Evacuation

๐Ÿ“š Source: QRH Back Cover.4 (D632W001-AAR, December 15, 2021)

Condition

An evacuation is needed.

QRH ๋’ทํ‘œ์ง€ โ€” ๋น„์ƒ์‹œ ์ฆ‰์‹œ ์ ‘๊ทผ ๊ฐ€๋Šฅ ์œ„์น˜

Checklist (PF/PM ์—ญํ•  ๋ช…์‹œ)

#ActionWho
1PARKING BRAKE โ€” SetC
2OUTFLOW VALVE switches (both) โ€” MANF/O
3OUTFLOW VALVE MANUAL switches (both) โ€” Hold in OPEN until outflow valve indications show fully open (๊ฐ์••)F/O
4FUEL CONTROL switches (both) โ€” CUTOFFC
5Advise the cabin to evacuateC
6Advise ATCF/O
7Engine fire switches (both) โ€” PullF/O
8APU fire switch โ€” Override and PullF/O
9If engine or APU fire observed/indicated: Related fire switch โ€” Rotate to the stop and hold 1 secondF/O

โ– โ– โ– โ–  (Checklist Complete)

Notes

  • ์ด ์ฒดํฌ๋ฆฌ์ŠคํŠธ๋Š” QRH ๋’ทํ‘œ์ง€์— ์ธ์‡„๋˜์–ด ์žˆ์Œ (๋น ๋ฅธ ์ ‘๊ทผ)
  • Step 3: Outflow Valve๋ฅผ ์—ด์–ด ๊ธฐ์ฒด๋ฅผ ๊ฐ์•• โ†’ ๋„์–ด ์—ด๊ธฐ ์ „ ๋‚ด์™ธ ์ฐจ์•• ํ•ด์†Œ
  • Step 5: PA ๋ฐฉ์†ก โ€œEVACUATE, EVACUATE, EVACUATEโ€ ๋˜๋Š” EVAC Horn ์‚ฌ์šฉ
  • Captain์ด ์–‘์ชฝ ์—”์ง„ Cutoff + ํƒˆ์ถœ ์ง€์‹œ, F/O๊ฐ€ ๊ฐ์•• + Fire Switch + ATC ๋‹ด๋‹น