Smoke or Fumes Removal

๐Ÿ“š Source: QRH 8.28~8.29 (D632W001-AAR)

Condition

Smoke or fumes removal is needed.

Checklist

  1. Smoke, Fire or Fumes ์ฒดํฌ๋ฆฌ์ŠคํŠธ์—์„œ ์ง€์‹œํ•  ๋•Œ๋งŒ ์ด ์ฒดํฌ๋ฆฌ์ŠคํŠธ๋ฅผ ์ˆ˜ํ–‰ํ•  ๊ฒƒ
  2. ์ฐฉ๋ฅ™์„ ์ง€์—ฐ์‹œํ‚ค๋ฉด์„œ๊นŒ์ง€ ์•„๋ž˜ ๋‹จ๊ณ„๋ฅผ ์™„๋ฃŒํ•˜๋ ค ํ•˜์ง€ ๋ง ๊ฒƒ
  3. Flight deck door โ€” Close
  4. EQUIP COOLING switch โ€” Off

Equipment Cooling Off ํ›„ 30๋ถ„

์ €๊ณ ๋„ยท์ €์ฐจ์••์—์„œ 30๋ถ„ ์ด์ƒ ์šด์˜ ์‹œ ์ „์ž์žฅ๋น„ ๋ฐ ๋””์Šคํ”Œ๋ ˆ์ด๊ฐ€ ๊ณ ์žฅ๋‚  ์ˆ˜ ์žˆ์Œ.

  1. ๋‹ค์Œ ์ฒดํฌ๋ฆฌ์ŠคํŠธ ์ˆ˜ํ–‰ ๊ธˆ์ง€: EQUIP COOLING OVRD
  2. ๋ถ„๊ธฐ:
graph TD
    A{์—ฐ๊ธฐ/์—ฐ๋ฌด ์œ„์น˜?} -->|๊ฐ์‹ค ์ „๋ฐฉ mid-wing ์•ž| B[Step 7: AFT Outflow Valve ๋‹ซ๊ธฐ]
    A -->|๊ฐ์‹ค ํ›„๋ฐฉ mid-wing ๋’ค| C[Step 10: FWD Outflow Valve ๋‹ซ๊ธฐ]

์—ฐ๊ธฐ๊ฐ€ ๊ฐ์‹ค ์ „๋ฐฉ์ธ ๊ฒฝ์šฐ (Step 7~9)

  1. AFT OUTFLOW VALVE switch โ€” MAN
  2. AFT OUTFLOW VALVE MANUAL switch โ€” Hold in CLOSE (AFT outflow valve ์™„์ „ ๋‹ซํž˜ ํ™•์ธ)
  3. OUTFLOW VALVE AFT ์ฒดํฌ๋ฆฌ์ŠคํŠธ ์ˆ˜ํ–‰ ๊ธˆ์ง€ โ†’ Smoke, Fire or Fumes ์ฒดํฌ๋ฆฌ์ŠคํŠธ๋กœ ๋ณต๊ท€

์—ฐ๊ธฐ๊ฐ€ ๊ฐ์‹ค ํ›„๋ฐฉ์ธ ๊ฒฝ์šฐ (Step 10~12)

  1. FWD OUTFLOW VALVE switch โ€” MAN
  2. FWD OUTFLOW VALVE MANUAL switch โ€” Hold in CLOSE (FWD outflow valve ์™„์ „ ๋‹ซํž˜ ํ™•์ธ)
  3. OUTFLOW VALVE FWD ์ฒดํฌ๋ฆฌ์ŠคํŠธ ์ˆ˜ํ–‰ ๊ธˆ์ง€ โ†’ Smoke, Fire or Fumes ์ฒดํฌ๋ฆฌ์ŠคํŠธ๋กœ ๋ณต๊ท€

โ– โ– โ– โ–  (Checklist Complete)

Notes

  • ํ•ต์‹ฌ ์›๋ฆฌ: ์—ฐ๊ธฐ๊ฐ€ ์žˆ๋Š” ์ชฝ์˜ ๋ฐ˜๋Œ€ํŽธ Outflow Valve๋ฅผ ๋‹ซ์•„์„œ ์—ฐ๊ธฐ๊ฐ€ ๋น ์ ธ๋‚˜๊ฐ€๋Š” ๊ฒฝ๋กœ๋ฅผ ๋งŒ๋“ฆ
  • ์ด ์ฒดํฌ๋ฆฌ์ŠคํŠธ ์™„๋ฃŒ ํ›„ ๋ฐ˜๋“œ์‹œ Smoke, Fire or Fumes ์ฒดํฌ๋ฆฌ์ŠคํŠธ์˜ ๋‚˜๋จธ์ง€ ๋‹จ๊ณ„๋กœ ๋ณต๊ท€