HYD PRESS SYS C
Condition: The center hydraulic system pressure is low. Objective: To restore system pressure and configure for landing using alternate systems, if needed.
Decision Flowchart
flowchart TD A["HYD PRESS SYS C"] --> B["Step 1: C1 or C2 AIR DEMAND<br/>pump selector — ON"] B --> C{"HYD PRESS SYS C<br/>message status?"} C -->|Message blanks| D["■ ■ ■ ■<br/>Checklist complete"] C -->|Message stays| E["Step 3: C2 ELEC PRIMARY pump — Off"] E --> F["Step 4: C1 & C2 AIR DEMAND selectors — OFF"] F --> G["Step 5: GND PROX FLAP OVRD — OVRD"] G --> H["Step 6: Do NOT accomplish:<br/>Auto Speedbrake, Spoilers"]
Checklist
- Step 1: C1 or C2 AIR DEMAND pump selector … ON
- Step 2: Choose one:
| HYD PRESS SYS C message blanks | HYD PRESS SYS C message stays shown |
|---|---|
| ■ ■ ■ ■ (Checklist complete) | → Go to Step 3 |
- Step 3: C2 ELEC PRIMARY pump switch … Off
- Step 4: C1 and C2 AIR DEMAND pump selectors … OFF
- Step 5: GND PROX FLAP OVRD switch … OVRD
- Step 6: Do not accomplish: AUTO SPEEDBRAKE, SPOILERS
Inoperative Items (Center System Loss)
WARNING
Center Hydraulic System Loss 시 사용 불가 항목:
- Primary flap and slat operation → Plan more time for slower flap/slat (alternate operation)
- Main landing gear hydraulic operation → Alternate gear extension 필요
- Main gear steering → Inoperative
- Auto speedbrake → Inoperative
- Spoilers → Reduced effectiveness
Related HYD Checklists
| EICAS Message | Condition | Section |
|---|---|---|
| HYD AUTO CONTROL C | Auto control of center demand pumps fails | 13.1 |
| HYD OVERHEAT PRI C1, C2 | Pump temperature high | 13.2 |
| HYD PRESS DEM C1, C2 | Demand pump output pressure low | 13.4 |
| HYD PRESS PRI C1, C2 | Primary pump pressure low | 13.4 |
| HYD PRESS PRI L | Left primary pump pressure low (L thrust reverser may be inop) | 13.4 |
| HYD PRESS PRI R | Right primary pump pressure low (R reverser, autobrake, normal brakes may be inop) | 13.5 |